120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles With Focusmist High Frequency Nebulization

Brand Name : FUNSONIC

Model Number : FSW-1203-L

Certification : CE

Place of Origin : CHINA

MOQ : 1 UNIT

Price : Negotation

Payment Terms : T/T, Western Union

Supply Ability : 1000 unit per month

Packaging Details : Packed by carton

Production Name : Ultrasonic Spraying Nozzle

Frequency : 120Khz

Max Power : 15w

Automized Particle Size Range : 15-40μm

Spray flow : 0.5-10ml/min

Liquid viscosity : <30cps

Particle size : <10μm

Application : Larger Solid Particles and Higher Solid Content Slurries

Contact Now

120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles with Focusmist High Frequency Nebulization

Description:

The gathering type ultrasonic nozzle is an ultrasonic atomizing nozzle with small spray width. The ultrasonic atomization nozzle technology is adopted, and the special contraction flow channel design will uniformly and centrally distribute the carrier gas, so that the ultrasonic atomized liquid mist is in the form of concentrated spray, thus reducing the spray area of the ultrasonic nozzle. Due to the small spraying width of the centralized ultrasonic nozzle, it is mainly suitable for various small and medium-sized spraying applications, complementing the Funsonic wide width spraying ultrasonic nozzle, and can be almost suitable for all different flat spraying requirements.

Parameters:

Model FSW-1203-L
Name 120Khz Gathering Ultrasonic Nozzle Atomization
Frequency 120Khz
Atomized particle size range(μm) 15-40
Spray width(mm) 2-20
Spray flow(ml/min) 0.5-10
Spray height(mm) 10-30
Liquid viscosity (cps) <30
Particle size (μm) <10
Diversion pressure (Mpa) <0.05
Application Suitable for Brackets, balloon conduits, wires, flux for selective welding applications, etc.

There is a certain correlation between the working frequency and amplitude of ultrasonic spraying machines and the viscosity of coatings. The viscosity of coatings refers to the degree of viscosity of coatings, which has a certain impact on the working frequency and amplitude of ultrasonic spraying machines. The following is the relationship between them:

1. Working frequency: Higher working frequencies are usually suitable for low viscosity coatings. This is because high-frequency vibrations can generate higher shear forces, effectively dispersing and spraying low viscosity coatings. For high viscosity coatings, higher frequencies may cause the coating to pass through the nozzle too quickly and not achieve sufficient dispersion.

2. Amplitude: The selection of amplitude is also closely related to the viscosity of the coating. Larger amplitudes are usually suitable for high viscosity coatings. Large amplitude vibration can provide stronger energy, making high viscosity coatings easier to disperse and spray. On the contrary, for low viscosity coatings, larger amplitudes may lead to excessive dispersion or spraying.

Overall, lower viscosity coatings typically require higher operating frequencies and smaller amplitudes, while higher viscosity coatings typically require lower operating frequencies and larger amplitudes. This can achieve effective dispersion and spraying of coatings, and ensure the uniformity and quality of the spraying effect.

However, the viscosity of the coating is only one of the factors that affects the selection of working frequency and amplitude. Other factors, such as the particle size, rheological properties, and required spraying effect of the coating, also need to be comprehensively considered. Therefore, in practical applications, it is recommended to conduct experiments and adjustments based on specific coating characteristics and technical parameters of ultrasonic spraying machines to find the optimal combination of working frequency and amplitude.

120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles with Focusmist High Frequency Nebulization

120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles With Focusmist High Frequency Nebulization

120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles With Focusmist High Frequency Nebulization


Product Tags:

High Frequency Spraying nozzle

      

120Khz Spraying nozzle

      

Ultrassonic Fuel Cell Spraying Coating Nozzles

      
China 120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles With Focusmist High Frequency Nebulization wholesale

120Khz Ultrassonic Fuel Cell Spraying Coating Nozzles With Focusmist High Frequency Nebulization Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hangzhou Qianrong Automation Equipment Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)